ORLAN SUPER

ORLAN wood gasification boilers are adapted to burn various wood granulation: wood logs, logs and chips. Sawdust and chips should be burned along with wood logs.

MORE
image01

ORLIGNO 200

ORLIGNO 200 boilers create a new pathway in wood gasifi cation boiler technology. Unique design as well as a range of design solutions to benefit the ease of use and aid customer satisfaction.

MORE
image01

ORLIGNO 400

The ORLIGNO 400 is a response to the ever-tightening of emissions and safety standards in a compromise with ...

MORE
image01



image01



Wood is a widely available fuel and also one of the least expensive resources. In the correct wood combustion process small amounts of harmful substances are produced, such as NOx, CO, Hydrocarbons, breathable dust and the amount of ash produced is about 1% of the mass of the fuel load (this depends on the dust content of the wood).

ORLAN wood gasification boilers are adapted to burn various wood granulation: wood logs, logs and chips. Sawdust and chips should be burned along with wood logs.

Technical parameters resulting from wood combustion processes meet the most rigorous European norms and provide nearly twice as much heat as traditional boilers or fireplaces. The appliances can work in open as well as pressurized systems in accordance with current regulations.

ORLAN SUPER boilers are designed for heating various types of buildings. They are commonly used in detached houses, drying facilities, industrial units and workshops.

ORLAN SUPER 96 or 130kW boilers allow the heating of larger areas such as large industrial buildings or public facilities.

image01




Boiler section

1. Hot water outlet
2. Boiler controller
3. Loading door
4. Fan
5. Fan casings
6. Combustion door
7. Firebricks
8. Combustion chamber
9. Tube heat exchanger
10. Nozzle
11. Cooling coil


image01


Boiler features

  • Up to 91% efficient
  • Range from 18 to 130kW
  • Large loading capacity
  • Length of wood logs:
  • - 50cm (18kW, 25kW, 40kW)
    - 75cm (60kW)
    - 100cm (80kW, 95kW, 130 kW)
  • Small amount of ash residue
  • Low maintenance costs
  • User-friendly construction
  • Up to 12 hours continuous operation
  • Modulated fan power 30-100%
  • Adjusted to work in pressurized systems thanks to cooling coil installed in upper part of boiler body
  • Electronic controller with possibility to connect remote EKOSTER CONTROL

image01




Technical data
Rated power [kW] 18 25 40 60 80 96 130
Efficiency [%] 91 90,5 91
Boiler class (EN 303-5) 5
ECODESIGN NO YES NO NO NO NO NO
Water capacity [dm³] 55 75 93 180 205 340 380
Water capacity [l] 55 75 93 180 205 340 380
Water capacity in the boiler [dm³] 85 120 185 310 465 605 605
Water capacity in the boiler [l] 85 120 185 310 465 605 605
Loading slot size width/length [mm] 225/380 260/432 260/432 285/580 285/580 285/580 285/580
Burning period [h] 7-12
Length of wood logs [cm] 50 50 50 75 100 100 100
Humidity – recommended [%] 15-25
Average fuel usage for:
- nominal power [kg/h] 6,8 8,2 10,1 15,1 19,8 20,3 24,5
Maximum operating pressure [bar] 3
Miniumum temperature of the return water [°C] 60
Temperature settings range [°C] 60-90
Protection level IP40
Voltage/Frequency [V/Hz] 230/50
Fumes features (at nominal power):
- fumes temerature [°C] 150-180 150-180 150-180 150-180 150-180 160-190 160-190
- fumes fow [kg/s] 0,0066 0,0088 0,0144 0,0216 0,0272 0,0332 0,0332
Required chimney draught [Pa] 15-20 15-25 15-20
Cooling water pressure required
at the infux to a heat exchanger [bar]
2
Cold water temperature in the heat exchanger [°C] 10
Recommended capacity of accumulation tank [l] 750-1500 1000-2000 2000-3000 3000-4000 4000-5000 4000-5000 5000-6000


image01
Dimensions
Boiler type [kW] 18 25 40 60 80 96 130
Total height [A - mm] 1220 1320 1570 1540 1540 1845 1845
Hot water outlet height [B - mm] 1210 1300 1560 1575 1590 1845 1845
Hot water inlet height [C - mm] 210 230 220 200 200 209 209
Waste outlet height [D - mm] 140 140 140 140 140 134 134
Chimney flue height [E - mm] 870 960 1210 1160 1170 1441 1441
Casing width [G - mm] 545 600 600 740 740 750 750
Total depth [H - mm] 960 1040 1040 1340 1700 1804 1880
Hot water outlet [I -mm] 340 310 300 570 600 734 798
Diameter of chimney flue [J - mm] 180 200 200 210 210 300 300
Total width [K - mm] 660 720 720 860 860 870 870
Hot water outlet [L - mm] 990 1100 1330 1310 1300 1310 1310
Cooling coil outlet [M - mm] 260 270 260 210 300 313 313
Diameter of feeding and return outlet [Q - inch] 2 2 2 2 2 2 2
Diameter of cooling coil tappings [R - inch] 3/4 3/4 3/4 3/4 3/4 1 1
Diameter of drain valve outlet [S - inch] 1/2 1/2 1/2 1/2 1/2 3/4 3/4


Controller
The EKOSTER 2 microprocessor temperature controller is designed to control the heating process and the activation of the circulation pump in the central heating installation.
image01
EKOSTER controller used in the ORLAN SUPER boiler



Controller features
The regulator fulfils the following tasks:
  • Maintains the preset boiler temperature through the heating control
  • Automatic control turn-off after boiler extinction
  • Blocking fan operation when stoking the boiler
  • Central heating circulation pump control
  • “COMFORT SYSTEM” - a system that prevents pump blockages when the boiler is not in operation
  • Protection from boiler freezing and overheating
  • Signalling when the boiler temperature sensor is damaged
  • Compatible with EKOSTER control remote control system



EKOSTER control
The EKOSTER control enables the constant temperature reading of the central heating boiler, adjustment of boiler temperature settings as well as activation and de-activation of control by regular communication with EKOSTER regulator. The innovative built-in alarm system informs the user with a piercing sound if the threshold of 97°C has been reached, if the boiler temperature has dropped below 0°C or if the sensor is damaged.



image01
Technical data
Range of temperatures displayed -9°C - + 99°C
Range of temperature settings +60°C - + 90°C

CRANP-KOVO s.r.o.
Miru 371, 790 70 Javornik
Czech Republic