Orligno 200

5th Class ProductEco Design

Paliwo Drewno, Brykiet
Zastosowanie Dom jednorodzinny, dom wielorodzinny, obiekty przemysłowe i użytkowe
Dostępne moce [kW] | 18 | 25 | 40 | 60 | 80 | 96 | 130 |
Inne produkty z tej grupy

Orlan Super
Orligno 200
Orligno 100 z układem pelletowym
Orligno 100

BOILER DESCRIPTION

ORLIGNO 200 boilers create a new pathway in wood gasifi cation boiler technology. Unique design as well as a range of design solutions to benefit the ease of use and aid customer satisfaction. Technical data resulting from wood combustion process meet the most rigorous European normsand provide nearly twice as much heat as traditional boilers or fireplaces. The appliances can work in open as well as pressurized systems in accordance with current regulations.

APPLICATION

ORLIGNO 200 boilers are designed to work in a variety of places. They are most commonly used in detached houses, drying facilities, industrial units

and workshops.

Available types are as follows: 18 kW, 25 kW, 40 kW, 60 kW, 80 kW, 96 kW and 130 kW

 

 STAGES OF WOOD GASIFICATION PROCESS

The wood gasification process in central heating boilers can be divided into four main phases:

STAGE 1

Drying and de-gassing wood at a temperature of 450°C.

STAGE 2

Combustion of the mixture of wood gas and secondary air at a temperature of 560°C.

STAGE 3

Burning up the flame and heat emission at a temperature of 1200°C.

STAGE 4

Exhaust gases removal trough the flue with a temperature of 160°C.

BOILER FEATURES:

  • Efficiency up to 91%
  • Low maintenance costs
  • User - friendly
  • Small amount of ash residue
  • Large loading capacity
  • Wood log length:
    – 50cm (18kW, 25kW, 40kW
    – 75cm (60kW)
    – 100cm (80kW, 95kW, 130kW)
  • Burning period up to 12h
  • Modulated fan power in a range 30 – 100%
  • Adjusted to operate in pressurized systems
  • Possibility to connect remote control EKOSTER CONTROL
  • Made of 8mm thick  high quality boiler steel P265
  • Environment friendly
  • Ceramics resistant to thermal shocks
  • 5 years warranty on boiler tightness

CHOOSING CORRECT BOILER BASED ON HEATING SPACE :

-An installation designer will estimate how much heat is required in the for the building.
-The result needs to be increased by 20% (so called boiler over-sizing)
-See the graphto give an indication which boiler may be suitable
Caution!
The graph is for information only and Cranp-Kovo company cannot
be held liable if a boiler with unsuitable power output
is selected.

CRANP-KOVO s.r.o.
Miru 371, 790 70 Javornik
Czech Republic
T: +420 584 492 800
e-mail: info@cranp-kovo.cz